4. Check the result of the Amplitude Control with SP1-902-002.
0: Success, 2: Failure due to no sampling data,
3: Failure due to insufficient number of pattern detections
When the result of this adjustment is "2" or "3":
• Check that all the PCUs are correctly set and that the image transfer belt unit is correctly set.
• Do the "Amplitude Control" again after checking the PCUs and image transfer belt unit.
When the result is still "2" or "3" after checking the PCUs and image transfer belt unit:
• Check that the gear unit is installed correctly.
5. Exit the SP mode.

Registration Motor

1. Rear cover (* p.109)
2. Right rear cover (* p.110)
3. Ventilation duct (* p.222)
4. Turn the harnesses aside (
5. Fusing power supply board fan bracket [A] ( x 2,
6. Registration motor assembly [B] ( x 3,
7. Registration motor [C] ( x 2, timing belt)
x 5)
x 1)
x 1)
Drive Unit
4