Image Adjustment; Registration - Ricoh AP-P2 G188 Field Service Manual

Table of Contents

Advertisement

Image Adjustment

Registration

Image Area
A = 5.2 mm (0.21"), B = 4.2 mm (0.17") C = 3.2 mm (0.13")
Make sure that the registration is adjusted within the adjustment standard range as shown above.
Leading Edge
Adjusts the leading edge registration for each paper type and process line speed.
Side to Side
Adjusts the side-to-side registration for each paper feed station. Use SP mode (SP1-002) to adjust the side-
to-side registration.
Adjustment Standard
• Leading edge (sub-scan direction): 5.2 ± 1.5 mm
• Side to side (main-scan direction): 2.0 ± 1 mm
Paper Registration Standard
The registration in both main- and sub-scan directions can change within the following tolerance.
Image Adjustment