8. Appendix: SP Mode Tables
Pre-Idling Time
002
Specifies the fusing rotation time before executing SP1109-001.
Stop Time
003
Specifies the time for measuring the nip.
Pressure Position
004
Specifies the pressure position for measuring the nip.
1110
[Pressure Release]
Shift Time
001
Adjusts the time when the pressure roller moves from the pressing position to the no-pressing
positon.
002 Feed Pressure: 1
003 Feed Pressure: 2
004 Feed Pressure: 3
8
005 SC Detection
1112
[Environmental Correction: Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction
Specifies the temperature correction for the heating roller. When the low temperature
003
condition (specified with SP1112-001) is detected, the value of this SP is added to the heating
roller temperature.
156
*ENG
[0 to 255 / 240 / 1 sec/step]
* ENG
[5 to 30 / 10 / 1 sec/step]
* ENG
[0 to 3 / 0 / 1 ]
*ENG
[0 to 240 / 1 / 1 min/step] DFU
*ENG
Not used
* ENG
[0 to 700 / 0 / 1 msec/step]
* ENG
DFU
* ENG
[0 or 1 / 1 / 1]
0: OFF, 1: ON
*ENG
[10 to 23 / 17 / 1 deg/step]
*ENG
[24 to 40 / 30 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]