High Temp. Correction
Specifies the temperature correction for the heating roller. When the high temperature
004
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
Reference Temp
Specifies the temperature correction for the heating roller. When the high temperature
005
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
006 Low Temp Correction a
007 Reference Temp Correction a
008 High Temp Correction a
009 Low Temp Correction b
010 Reference Temp Correction b
011 High Temp Correction b
1113
[Stand-by Time]
Shift Time
Specifies the interval from the ready mode to the stand-by mode.
001
If the machine does not do any printing job for the time specified with this SP after the heating
roller has reached the ready temperature, the machine returns to the stand-by mode.
After Recovery
003
Specifies the time for keeping the target temperature after recovery (SP1105-083) without
any jobs.
004 Time After Paper Feed
006 Offset: Center and Ends
1115
[Stand-by Idling]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[15 to 25 / 20 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 15 / 10 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 180 / 60 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 10 / 0 / 1 sec/step]
*ENG
[0 to 100 / 100 / 1 deg/step]