The laser synchronizing detection signal for the start position of the LDB [K], [Y], [M],
[C] is not output for two seconds after LDB unit turns on while the polygon motor is
rotating normally.
• Disconnected cable from the laser synchronizing detection unit or defective
connection
• Defective laser synchronizing detector
-
-
• Defective LDB
• Defective BCU
1. Check the connectors.
2. Replace the laser-synchronizing detector.
3. Replace the LDB.
4. Replace the BCU.
No.
Type
FGATE ON error: Bk
The PFGATE ON signal does not assert within 5 seconds after processing the image
in normal job or MUSIC for start position [K].
• Defective ASIC (Lupus)
230
D
• Poor connection between controller and BCU.
• Defective BCU
1. Check the connection between the controller board and the BCU.
2. Replace the BCU.
3. Replace the controller board.
No.
Type
FGATE OFF error: Bk
• The PFGATE ON signal still asserts within 5 seconds after processing the image
in normal job or MUSIC for end position [K].
231
D
• The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)