Registration Motor - Ricoh MPC 2800 AT-C2 Field Service Manual

Table of Contents

Advertisement

4. Check the result of the Amplitude Control with SP1-902-002.
0: Success, 1: Failure due to no sampling data,
2: Failure due to insufficient number of pattern detections
When the result of this adjustment is "1" or "2":
• Check that all the PCUs are correctly set and that the image transfer belt unit is correctly set.
• Do "Amplitude Control" again after checking the PCUs and image transfer belt unit.
When the result is still "1" or "2" after checking the PCUs and image transfer belt unit:
• Check that the gear unit is installed correctly.
5. Exit the SP mode.

Registration Motor

1. Rear cover (* "p.169")
2. Right rear cover (* "p.170")
3. Ventilation duct (* "p.292")
4. Turn the harnesses aside ( x 5)
5. Fusing power supply board fan bracket [A] ( x 2,  x 1)
6. Registration motor assembly [B] ( x 3,  x 1)
7. Registration motor [C] ( x 2, timing belt)
Drive Unit