8. Appendix: SP Mode Tables
Magnification
010
Adjusts the magnification threshold for line position adjustment. If the length of the main scan
is changed by this amount since the previous MUSIC, then MSUIC is done again.
Temp. 2
Adjust the temperature change threshold for the line position adjustment (Mode a: adjustment
011
twice). The timing for line position adjustment depends on the combinations of several
conditions.
Time 2
012
Adjust the time threshold for the line position adjustment (Mode a: adjustment twice). The
timing for line position adjustment depends on the combinations of several conditions.
Page: Power ON:BW+FC
Adjusts the threshold of the line position adjustment for BW and FC printing mode at power-
013
on. The line position adjustment is done when the number of outputs in BW and color printing
mode reaches the value specified with this SP and the condition of SP2-193-008 or
SP2-193-009 is satisfied.
2194
[MUSIC Execution Result] Line Position Adjustment: Execution Result
8
001 Year
002 Month
003 Day
004 Hour
005 Minute
006 Temperature
007 Execution Result
008 Number of Execution
009 Number of Failure
204
*ENG
[0 to 10 / 0.1 / 0.01%/step]
*ENG
[0 to 100 / 10 / 1deg/step]
*ENG
[1 to 9999 / 600 / 1 minute/step]
*ENG
[0 to 999 / 200 / 1 page/step]
*ENG
[0 to 99 / 0 / 1 year/step]
*ENG
[1 to 12 / 1 / 1 month/step]
*ENG
[1 to 31 / 1 / 1 day/step]
*ENG
[0 to 23 / 0 / 1 hour/step]
*ENG
[0 to 59 / 0 / 1 minute/step]
*ENG
[0 to 100 / 0 / 1 deg/step]
[0 or 1 / 0 / 1 /step]
*ENG
0: Completed successfully, 1: Failed
*ENG
[0 to 999999 / 0 / 1 times/step]
*ENG
[0 to 999999 / 0 / 1 times/step]