Ricoh AP-P2 G188 Field Service Manual page 572

Table of Contents

Advertisement

8. Appendix: SP Mode Tables
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
007
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
RCG Connect Timeout
008
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 10 / 1 second /step]
RCG Write Timeout
009
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
RCG Read Timeout
010
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
Port 80 Enable
8
Enables/disables access via port 80 to the SOAP method.
011
[0 or 1 / 0 / – ]
0: Disabled, 1: Enabled
RFU (Remote Frimware Update) Timing
Selects the RFU timing.
013
[0 or 1 / 1 / – ]
0: RFU is executed whenever update request is received.
1: RFU is executed only when the machine is in the sleep mode.
RCG – C Registed
This SP displays the Embedded RC Gate installation end flag.
021
0: Installation not completed
1: Installation completed