Ricoh AP-P2 G188 Field Service Manual page 440

Table of Contents

Advertisement

8. Appendix: SP Mode Tables
2112
[TM/ID Sensor Check] ID Sensor Check FA
001 Execute
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C or Y.
2117
These SPs must be used when a new laser optics housing unit is installed or when SC285
occurs. For details, see "Laser Optics Housing Unit" in the "Replacement and Adjustment"
section.
001 Pulse: M
002 Pulse: C
003 Pulse: Y
2118
[Skew Adjustment]
001 Execute: M
8
002 Execute: C
003 Execute: Y
[Skew Adjustment Display]
2119
Displays the current skew adjustment value for each skew motor.
001 M
002 C
003 Y
[Thick Paper Skew Adj] Not used
2120
Selects the skew adjustment value for thick paper.
182
[0 or 1 / 0 / 1 /step]
This SP is used to check the ID sensors at the factory.
The results of this SP are displayed in SP2140 to
SP2145.
*ENG
*ENG
[–50 to 50 / 0 / 1 pulse/step]
*ENG
*ENG
Changes the current skew adjustment values to the
values specified with SP2117.
*ENG
These SPs must be used when a new laser optics
housing unit is installed or when SC285 occurs. For
details, see "Laser Optics Housing Unit" in the
*ENG
"Replacement and Adjustment" section.
*ENG
*ENG
[–50 to 50 / 0 / 1 pulse/step]
*ENG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap-p2 g189

Table of Contents