Uniden BCD996XT User Manual page 476

Hide thumbs Also See for BCD996XT:
Table of Contents

Advertisement

This command is invalid when the scanner is in Menu Mode, during Direct Entry
operation, during Quick Save operation.
FUNCTION
UASD specifies arbitrary frequency and changes to Quick Search Hold (VFO)
mode.
Parameter, such as STP, changes the contents of Srch/CloCall option.
<COMMAND CSC>
Go to Custom search and get reception status
Controller → Radio
CSC,ON[\r]
CSC,OFF[\r]
Radio → Controller
① CSC,[RSSI],[FRQ],[SQL][\r]
CSC,[RSSI],[FRQ],[SQL][\r]
CSC,[RSSI],[FRQ],[SQL][\r]
....
....
....
CSC,[RSSI],[FRQ],[SQL][\r]
CSC,OK[\r]
[RSSI]
[FRQ]
[SQL]
This command outputs custom search status of each frequency sequentially.
Use CSC,OFF command to stop the output.
This command is invalid when the scanner is in Menu Mode, during Direct Entry
operation, during Quick Save operation.
<COMMAND PWR>
*Get RSSI Level
Controller → Radio
PWR[\r]
Radio → Controller
PWR,[RSSI],[FRQ][\r]
[RSSI]
[FRQ]
Returns current RSSI level and its frequency.
The order of the frequency digits is from 1 GHz digit to 100 Hz digit.
: RSSI A/D Value
: Current Frequency
: Squelch Status
: RSSI A/D Value (0-1023)
: Current Frequency
227
(0-1023)
(0:CLOSE / 1:OPEN)