Chapter 8: Replacing Modules
194
The next example is from replacing an AT-XEM2-12XT Card with
an AT-XEM2-1CQ Card:
Console Message:
23:26:02 awplus HSL[996]: Stack member 1 must be
rebooted to configure for AT-XEM2-1CQ, disabling
XEM.
Buffered log:
2018 May 15 23:26:02 local6.crit awplus HSL[996]:
Stack member 1 must be rebooted to configure for
AT-XEM2-1CQ, disabling XEM.
This procedure requires a #2 Phillips-head screwdriver (not provided). The
illustrations show the AT-XEM2-12XT line card. The procedure is the
same for all cards.
To remove an AT-XEM2 Line Card from the switch, perform the following
procedure:
1. Label and remove the cables from the line card.
2. If the line card has fiber optic transceivers, install dust covers on the
ports.
3. If the line card has transceivers or direct connect cables, label and
remove them.
Warning
The temperature of an operational transceiver may exceed 70° C
(158° F). Exercise caution when removing or handling transceivers
with unprotected hands.  E43
Note
100Gbps transceivers for the AT-XEM2-1CQ Line Card have
handles. Use the handles when installing or removing transceivers.
4. Use a #2 Phillips-head screwdriver to loosen the two screws on the
faceplate of the card. Refer to Figure 116 on page 195.