Table 21. Hot-swapping Guidelines for XEM2 Line Cards (Continued)
XEM2 Line Card
AT-XEM2-1CQ
(Continued)
Here are additional hot-swapping guidelines:
Allied Telesis recommends saving a backup copy of the switch's
configuration file before removing or replacing XEM2 Line Cards.
For instructions, refer to the Software Reference for SwitchBlade
x908 GEN2 Switches.
When hot-swapped, XEM2 Line Cards might require up to thirty
seconds to become fully operational.
Remember to save the switch's configuration with the WRITE FILE
command after issuing the SWITCH BAY PROVISION command
to provision a line card slot for a card.
AlliedWare Plus alerts you with critical log messages on the
console and in the buffered log if you need to reset the switch after
hot-swapping line cards. (The buffered log is displayed with the
SHOW LOG command.) Here are examples of the messages. The
first example is from replacing an AT-XEM2-1CQ Card with an AT-
XEM2-12XT Card:
Console Message:
23:22:28 awplus HSL[996]: Stack member 1 must be
rebooted to configure for AT-XEM2-12XT, disabling
XEM.
Buffered log:
2018 May 15 23:22:28 local6.crit awplus HSL[996]:
Stack member 1 must be rebooted to configure for
AT-XEM2-12XT, disabling XEM.
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
Description
You must reset the switch after hot-
swapping the card under these conditions:
- Installing the AT-XEM2-1CQ Card in a
line card slot that was not provisioned
for it.
- Replacing one of the other cards with
the AT-XEM2-1CQ Card.
- Replacing the AT-XEM2-1CQ Card with
one of the other cards.
- Provisioning a line card slot for the AT-
XEM2-1CQ Card with the SWITCH BAY
PROVISION command. The provision is
not implemented until the switch is
reset.