Eco-Friendly Button; Reset Button; Figure 5: Switch Id Led - Allied Telesis AT-SBx908 Installation Manual

Table of Contents

Advertisement

Chapter 1: Overview
eco-friendly
Button

Reset Button

32
The chassis is booting up.
The chassis has encountered a fault condition.
The chassis is operating as a stand-alone switch, with the
ID number 1.
The chassis is a member of a VCStack and has
an ID number in the range of 1 to 4.
The dot in the lower right corner flashes when the switch
accesses USB memory.
The switch displays the letter "F" for fault on the ID LED if it detects one of
the following problems:
A cooling fan has failed.
The internal temperature of the switch has exceeded the normal
operating range and the switch may shut down.
Note
You can use the SHOW SYSTEM ENVIRONMENT command in the
command line interface to identify the source of the problem.
You use the eco-friendly button on the management panel to turn the
LEDs on or off. You can turn off the LEDs when you are not using them to
monitor the control and Ethernet line cards, to conserve electricity. When
the LEDs are off, the overall power consumption of the switch is slightly
reduced by approximately 2 watts.
The button controls all the port LEDs on the Ethernet line cards and
management panel, except for the L/A LED for the NET MGMT port. The
button does not control the LEDs on power supply systems.
Pressing the Reset button resets all the Ethernet line cards in the switch.
You might perform this function if the switch and line cards are
experiencing a problem.
Figure 5. Switch ID LED