8

Commissioning

8
Commissioning
The following applies for commissioning of a system into which this handling system is integrated.
8.1
Safety instructions
Note
Guides of the handling system can be damaged.
The planar surface gantry or three-dimensional gantry may only be placed in operation
after it is aligned and checked
(è 5 Installation of the planar surface gantries and the three-dimensional gantries).
Note
The following conditions must be fulfilled for commissioning:
– The handling system is completely mounted.
– The handling system is aligned and checked.
– The electrical installation is complete and checked.
– The pneumatic installation is complete and checked.
Commissioning may only be performed by qualified specialized personnel who are famil­
iar with the following:
– Festo Configuration Tools (FCT)
– installation and operation of electrical control systems
– installation and operation of pneumatic systems
– installation and operation of handling systems
– documentation for the product.
For support:
• Contact your regional Festo contact person.
Additional information è www.festo.com/sp.
Note
The power supply is not switched off.
Damage to the product from incorrect handling.
• Never pull the plug connectors and electrical interfaces when powered.
• Never connect the plug connectors and electrical interfaces when powered.
• Observe the handling specifications for electrostatically sensitive devices.
Warning
The danger zone of the system is not sufficiently secured against access and contact
with moving parts.
Injury due to impact or pinching.
• Before commissioning, take corresponding safeguarding measures in order to fulfil
fundamental safety and health protection requirements.