5
Installation of the planar surface gantries and the three-dimensional gantries
Prepare mounting option on mounting surface.
Mounting kit is movable. If required, change dimension X2.
EHMX-EGC-
Dimensions [mm]
Y1
Y2
X1
X2
X3
G1
Depth of thread 6
1) By = width in Y-direction (è 1.1 Technical data)
2) Hx = stroke in X-direction (è 1.1 Technical data)
3) n = total number of mounting components for both X-axes (è 5.1.2 Number n of mounting components)
For X-module with motor position in the middle:
Caution
Unfastened motor in the middle turns with the shaft.
Injury due to impact or pinching. Damage to the product.
Place motor outside the movement range.
Fasten gear unit sufficiently.
Prepare mounting option.
The drive shafts of the gear units and the hollow shafts must be sufficiently aligned
(è 5.6.1 Mounting of the connecting shaft).
EHMX-EGC-...-M
Dimensions [mm]
H1
L
B
G2
Depth of thread G2 14
Festo – GDCP-YXC-EN – 1506a – English
50
1)
By + 108
60
2)
Hx + 51
3)
(X1 – X3) / [(n / 2) – 1]
50
M3
80
– 0.5
70
M8
80
120
By + 182
By + 280
100
160
Hx + 146
Hx + 224
68
106
M5
M8
8
13
120
7.6
100
M10
16
185
By + 386
200
Hx + 310
106
M8
13
185
26.5
110
M10
20
49