5
Installation of the planar surface gantries and the three-dimensional gantries
Requirements
– Mounting surface is prepared (è 5.1.3 Preparation of the mounting surface).
– Transport protection in the shipping crate is removed
(è 2.4.1 Securing in the transport protection crate).
– Transport lock for lifting is mounted (è 2.4.2 Securing when lifting).
– Function of the mounting components is known
(è 5.2.1 Mounting kit without adjustment possibility/5.2.2 Adjusting kit).
Mounting
1. The slides of the X-module are blocked with motor position left/right. To be able to move the slides
for alignment:
– For motor with brake.
Remove motor (è 5.7 Motor with brake (EMMS-...-RSB/RMB).
– For motor without brake
Remove connector at the end of the respective motor cable.
2. Place X-axes slowly and carefully onto the prepared mounting surface.
Check:
– The guide rails lie inside.
1
1
Guide rail
3. Lightly clamp X-axis with energy chain to the mounting surface.