Installation of the planar surface gantries and the three-dimensional gantries
Mounting
The bolts define the position of the Y-module in the Z-direction.
• Have the premounted bolt 1 fastened. Do not unscrew it.
1. Unscrew screws 3 on the adapters:
– Both adapters can be moved.
2. Move adapters onto the position of the slides
on the X-module.
1
Bolt
(2x)
2
Adapter
(2x)
3
Screw
(6x ... 8x)
3. Place Y-module onto X-module:
– Motor position of the Y-module is on the side of the energy chain on the X-module.
1
X-module
4. Place centring sleeves (2x each) in the centring holes.
5. Fasten Y-module with the screws. Evenly tighten all screws (12x).