5
Installation of the planar surface gantries and the three-dimensional gantries
For adjusting kit
Ensure flat and horizontal mounting surface: flatness 2 mm
Prepare mounting option on mounting surface.
Adjusting kit is movable. If required, change dimension X2.
EHMX-EGC-
Dimensions [mm]
Y1
Y2
X1
X2
G1
Depth of thread G1 13
1) By = width in Y-direction (è 1.1 Technical data)
2) Hx = stroke in X-direction (è 1.1 Technical data)
3) n = total number of mounting components for both X-axes (è 5.1.2 Number n of mounting components)
50
50
1)
By + 110
62
2)
Hx + 1
3)
(X1) / [(n / 2) – 1]
M8
80
120
By + 186
By + 260
104
140
Hx + 78
Hx + 118
Festo – GDCP-YXC-EN – 1506a – English
185
By + 395
209
Hx + 204