Festo YXC Series Description page 86

Handling system
Hide thumbs Also See for YXC Series:
Table of Contents

Advertisement

5
Installation of the planar surface gantries and the three-dimensional gantries
Note
Incorrect mounting can cause material damage and malfunction.
Collision with Y-module or Z-module if the connecting shaft is mounted to the wrong side.
• Mount connecting shaft only to the drive side
(è 5.3.2 Mounting of the Y-module EHMY-RP),
(è 5.4
Installation of the planar surface gantries and the three-dimensional gantries (completely mounted)).
Couplings slide if the contact surfaces are not dry and free of grease.
• Clean contact surfaces on the following components:
– Connecting tube
– Couplings
– Drive shafts (leave expanding mandrel cone greased on the inside).
– Hollow shafts on the X-axes
– Drive shafts on the gear unit
Check connecting tube and couplings for
1.
excellent condition.
Check: no kinks, dents, deflections.
Insert a screwdriver into the cut-out.
2.
Lift off covers at the hollow shafts.
3.
86