Installation of the planar surface gantries and the three-dimensional gantries
5.1.3

Preparation of the mounting surface

For mounting kit without adjustment possibility
• Ensure mounting surface is flat and horizontal:
The required flatness depends on the size of the handling system.
Flatness
X1
[mm]
48
Y1
3 1000
3 1000
0.1
1001 ... 2000 0.2
2001 ... 3000 0.3
3001 ... 4000 0.4
4001 ... 5000 0.5
[mm]
1001 ... 2000
2001 ... 3000
0.2
0.3
0.4
0.6
0.6
0.9
0.8
1.2
1.0
1.5