Festo YXC Series Description page 66

Handling system
Hide thumbs Also See for YXC Series:
Table of Contents

Advertisement

5
Installation of the planar surface gantries and the three-dimensional gantries
10.Check alignment.
Check:
– The undersides of the X-axes must lie entirely in a theoretical plane with the required flatness.
The required flatness depends on the size.
Flatness
1)
X1
[mm]
1) Calculation of the dimensions Y1 and X1, depending on the mounting component (è 5.1.3 Preparation of the mounting surface)
The height offset can be adjusted only with adjusting kits. For mounting kits without ad­
justment, the mounting surface must be correspondingly flat.
66
1)
Y1
3 1000
3 1000
0.1
1001 ... 2000 0.2
2001 ... 3000 0.3
3001 ... 4000 0.4
4001 ... 5000 0.5
[mm]
1001 ... 2000
2001 ... 3000
0.2
0.3
0.4
0.6
0.6
0.9
0.8
1.2
1.0
1.5