Table 25. Configuring Member Switches - Part II (Continued)
Step
2
Enter the ENABLE command to move from the User Exec mode to the Privileged
Exec mode.
awplus> enable
Steps 3 and 4 set the switch's priority value to be the same as its ID number.
3
Move to the Global Configuration mode with the CONFIGURE TERMINAL command.
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
4
Assign a priority value to the switch equal to its ID number, with the STACK
PRIORITY. This example assigns priority 2 to a member switch with the ID 2:
awplus(config)# stack 2 priority 2
Steps 5 and 6 remove the stacking function from the default stacking ports 17 and 21 on the
member switch.
5
Enter the port Interface modes of the default stacking ports 17 and 21 on the member
switch. The example here assumes the member switch has the ID 2:
awplus(config)# interface port2.0.17-2.0.21
% port1.0.17 is currently configured as a stack-port. Use caution
when altering its config.
% port1.0.21 is currently configured as a stack-port. Use caution
when altering its config.
6
Remove the stacking function from the ports to convert them into regular Ethernet
ports, with the NO STACKPORT command:
awplus(config-if)# no stackport
% Save the config and restart the system for this change to take
effect.
Steps 7 and 8 add the stacking function to the optional stacking ports on the member switch.
7
Enter the Interface modes of the optional stack ports on the member switch. If you
filled out the worksheet in Table 19 on page 76, refer there for the ports. The example
command here assumes the switch has the ID 2 and will be using ports 15 and 16 for
the stack trunk. Be sure to modify the command with the ports you selected for the
stack trunk.
awplus(config-if)# interface port2.0.15-1.0.16
AT-x550 Series Installation Guide for Virtual Chassis Stacking