Advanced Settings and Features
Low Limit Pr (Pressure)
The low limit pressure feature requires a pressure transducer to monitor product pressure during application
and will allow the operator to set the lowest pressure tolerable during field operations. If the application system
reaches the low limit pressure, the field computer will display an alert and application system will maintain the
flow rate to keep the boom pressure consistent and to maintain the spray pattern.
The low limit pressure feature will result in higher than desired application rates. If the low limit pressure
feature will be used during field operations, be sure to enter a value that will not interfere with normal field
application.

Application Area

The application area on the CAN Controller Status screen displays the current application type and control
valve type configured on for the Viper Pro control system.
Refer to the Application and Control Valve Type(s) section on page 40 for information on these settings.