  • Page 1 Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer) 016-2005-005 Rev. A 3/2021 E35630 Copyright 2021...
  • Page 2 Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services. Raven Industries accepts no responsibility for the use of any of these signals or services for other than the stated purpose.
  • Page 3: Table Of Contents

    Table of Contents Chapter 1 Important Information..................1 Safety ....................................1 Agricultural Chemical Safety .............................. 2 Electrical Safety ..................................2 Touch Screen .................................... 2 Recommendations and Best Practices ........................ 3 Harness Routing ..................................3 Chapter 2 Introduction......................5 Make and Model Compatibility ..........................
  • Page 4 Table of Contents Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 5: Important Information

    • Do not operate this Raven system or any agricultural equipment while under the influence of alcohol or an illegal substance. • Be alert and aware of surroundings and remain in the operator seat at all times when operating this Raven system.
  • Page 6: Agricultural Chemical Safety

    • Do not connect the power leads to the battery until all system components are mounted and all electrical connections are completed. • Always start the machine before initializing this Raven system to prevent power surges or peak voltage. • To avoid tripping and entanglement hazards, route cables and harnesses away from walkways, steps, grab bars, and other areas used by the operator or service personnel when operating or servicing the equipment.
  • Page 7: Recommendations And Best Practices

    The word “harness” is used to describe any electrical cables and leads, both bundled and unbundled. Use the following guidelines and recommendations when connecting and routing harnesses while installing or maintaining this Raven system: • Leave protective caps/covers over harness connectors until needed to avoid dirt and moisture from contaminating electrical circuits.
  • Page 8 CHAPTER 1 Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 9: Introduction

    I NTRODUCTION CHAPTER C H A P T E R 2 MAKE AND MODEL COMPATIBILITY Hawkeye® 2 is a pressure-based product control system and allows for precise sprayer application over a range of conditions and reduced spray drift. Each nozzle is controlled by an individual pulsing valve giving you a consistent spray pattern as speed and conditions change.
  • Page 10: Installation Overview

    The following components must be installed with the Hawkeye® 2 nozzle control system: • Updated software on field computers or control monitors • PWM pump control valve • Raven compatible flow meter • Raven compatible pressure transducer • 80 (or finer) mesh strainer NOTE: Air induction style spray tips should not be used with the Hawkeye®...
  • Page 11: Kit Contents

    CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID BOOM, CNH, 120' / 20", HAWKEYE 2 115-2005-006 CABLE, OUTER BOOM, CNH, 120' / 20", HAWKEYE 2 115-2005-007 KIT, HAWKEYE 2 SYSTEM SERVICE, WILGER...
  • Page 12 SHEET, WARRANTY/HELP (016-0171-638 & 016-0171-714) 016-0171-649 RCM, HAWKEYE 2 063-0173-956 115-2005-077 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH, 100'/20", HAWKEYE 2 115-2005-121 CABLE, OUTER, CNH, 100'/20", HAWKEYE 2 115-2005-122 KIT, HAWKEYE 2 SYSTEM SERVICE, WILGER...
  • Page 13 RCM, HAWKEYE 2 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH, 100' / 20", HAWKEYE 2 115-2005-121 115-2005-206 CABLE, OUTER, CNH, 90' / 20", HAWKEYE 2 KIT, HAWKEYE 2 SYSTEM SERVICE, WILGER...
  • Page 14 CHAPTER 2 FIGURE 4. Hawkeye® 2 Case IH Patriot/Trident MY17+, 120’/10” Boom Kit Components (P/N 117-2005- 004 Rev. A) Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 15 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 115-2005-006 CABLE, MID BOOM, CNH, 120' / 20", HAWKEYE 2 CABLE, OUTER BOOM, CNH, 120' / 20", HAWKEYE 2 115-2005-007 KIT, HAWKEYE 2 SYSTEM SERVICE, ARAG/HYPRO 117-2005-051...
  • Page 16 SHEET, WARRANTY/HELP (016-0171-638 & 016-0171-714) 016-0171-649 RCM, HAWKEYE 2 063-0173-956 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH, 100'/20", HAWKEYE 2 115-2005-121 CABLE, OUTER, CNH, 100'/20", HAWKEYE 2 115-2005-122 KIT, HAWKEYE 2 SYSTEM SERVICE, ARAG/HYPRO...
  • Page 17 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH LATAM, 36M/50cm, HAWKEYE 2 115-2005-297 CABLE, OUTER BOOM, CNH, 120' / 20", HAWKEYE 2 115-2005-007 KIT, HAWKEYE 2 SYSTEM SERVICE, TEEJET 117-2005-050 BRACKET, RCM, PATRIOT 107-0172-670...
  • Page 18 063-0173-956 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH, 100' / 20", HAWKEYE 2 115-2005-121 CABLE, OUTER, CNH, 100' / 20", HAWKEYE 2 115-2005-122 KIT, HAWKEYE 2 SYSTEM SERVICE, TEEJET...
  • Page 19 063-0173-956 115-2005-077 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH, 100' / 20", HAWKEYE 2 115-2005-121 CABLE, OUTER, CNH, 90' / 20", HAWKEYE 2 115-2005-206 KIT, HAWKEYE 2 SYSTEM SERVICE, TEEJET...
  • Page 20 NUT, FLANGED LOCK, M6-1, ZINC COATING 312-4000-216 WASHER, M6, ZINC COATING 313-1000-046 (LABELED BOX 2 OF 5) CABLE, INNER, CNH, 100' / 20", HAWKEYE 2 115-2005-120 (LABELED BOX 3 OF 5) CABLE, INNER, CNH, 100' / 20", HAWKEYE 2 115-2005-120...
  • Page 21 NUT, FLANGED LOCK, M6-1, ZINC COATING 312-4000-216 WASHER, M6, ZINC COATING 313-1000-046 (LABELED BOX 2 OF 5) CABLE, INNER, CNH, 100' / 20", HAWKEYE 2 115-2005-120 (LABELED BOX 3 OF 5) CABLE, INNER, CNH, 100' / 20", HAWKEYE 2 115-2005-120...
  • Page 22 BOX, SHIPPING (LABELED BOX 1 OF 5) 053-0159-197 RCM, HAWKEYE 2 063-0173-956 CABLE, PROD CONTROL, PATRIOT, HAWKEYE 2 115-2005-077 CABLE, NCV POWER, PATRIOT, HAWKEYE 2, MY17+ 115-2005-078 CABLE, MID, CNH LATAM, 32M/50CM, HAWKEYE 2 115-2005-121 CABLE, OUTER BOOM, CNH, 32M/50CM, HAWKEYE 2 115-2005-301...
  • Page 23: Updates

    Fuse, Mini-Blade Type 15 Amp 510-1003-041 UPDATES Raven software and documentation updates may be made available periodically on the Raven Applied Technology web site: www.ravenhelp.com At Raven Industries, we strive to make your experience with our products as rewarding as possible.
  • Page 24 CHAPTER 2 Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 25: Chapter 3 Installation Preparation

    I NSTALLATION PREPARATION CHAPTER C H A P T E R 3 Perform the following procedure to prepare the implement for installation of the Hawkeye® 2 nozzle control system. CAUTION Chemical residues may be present. Thoroughly bleed pressure from chemical lines and rinse the system with clean water prior to installing or servicing fittings, hoses, valves, or nozzles in the application system.
  • Page 26 CHAPTER 3 FIGURE 1. Nozzle Body Cap and Diaphragm Removed Cap and Diaphragm Removed Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 27: Chapter 4 Hawkeye® 2 Ncv And Boom Cable Installation

    H AWKEYE® 2 NCV AND BOOM CHAPTER C H A P T E R 4 CABLE INSTALLATION HAWKEYE® 2 NOZZLE CONTROL VALVE INSTALLATION BEST PRACTICES AND RECOMMENDATIONS • Do not connect battery leads until all cables are installed and connected. •...
  • Page 28: Boom Cable Routing And Connection

    CHAPTER 4 BOOM CABLE ROUTING AND CONNECTION BEST PRACTICES AND RECOMMENDATIONS • Route the Hawkeye® 2 inner, mid, and outer boom cables along existing cables or plumbing to avoid cable damage. • Route cables to avoid pinch points and to avoid stretching the cable during folding and unfolding operations. Pay special attention to cable routing near folding or break-away points.
  • Page 29 HAWKEYE® 2 NCV AND BOOM CABLE INSTALLATION NOTE: Keep the boom connections clean and off the ground while routing. Do not secure cables with cable ties until all cables are in place and routings are checked for pinch points and other interferences. Ensure sufficient slack is available at fold and break-away joints to allow for full range of motion without stretching the cable.
  • Page 30 CHAPTER 4 8. Once all boom cables are routed along the boom as desired, begin connecting the boom cables to the Hawkeye® 2 NCVs previously installed. 9. Use provided cable ties to secure the boom cables to the boom components as needed to ensure they are secure.
  • Page 31: Chapter 5 Rcm - Sprayer Mounting And Connection

    R CM - SPRAYER MOUNTING CHAPTER C H A P T E R 5 AND CONNECTION MOUNTING PLATE PREPARATION 1. Locate the Product Controller II (PCII) ECU mounted on the rear center rack of the sprayer. FIGURE 1. PCII ECU and Power Management Module Fasteners Securing Relays Hawkeye®...
  • Page 32: Rcm - Sprayer Installation

    CHAPTER 5 RCM - SPRAYER INSTALLATION INSTALL THE MOUNTING PLATE AND RCM - SPRAYER 1. Locate the RCM - Sprayer mounting bracket (P/N 107-0172-670), M6 flathead screws, and flanged lock nuts provided with the Hawkeye® 2 kit. 2. Using the flathead screws and lock nuts provided, secure the RCM - Sprayer mounting plate to the ECU bracket where the PCII was previously removed.
  • Page 33: Install The Rcm - Sprayer & Power Cables

    RCM - SPRAYER MOUNTING AND CONNECTION INSTALL THE RCM - SPRAYER & POWER CABLES 1. Locate the RCM - Sprayer cable (P/N 115-2005-077) provided in the kit. 2. Identify the three RCM - Sprayer connectors (two black, one gray) and connect these to the RCM - Sprayer. FIGURE 4.
  • Page 34 CHAPTER 5 4. Connect the connector labeled “ECU Power” to the mating 2-pin receptacle near the top of the center rack frame where the PCII ECU cable was previously connected, as shown in Figure 6, “ECU Power Connection,” below. FIGURE 6. ECU Power Connection 5.
  • Page 35: Leak Test

    RCM - SPRAYER MOUNTING AND CONNECTION 10. Connect the round 19-pin connectors labeled “Left Boom” and “Right Boom” to their respective inner boom cables installed previously, as shown in Figure 7, “Left and Right Inner Boom Cable Connections,” below. FIGURE 7. Left and Right Inner Boom Cable Connections 11.
  • Page 36 CHAPTER 5 Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 37: Chapter A System Diagram

    S YSTEM DIAGRAM APPENDIX C H A P T E R A SYSTEM DIAGRAM The system diagram is shown on the next page. System Diagram: System diagram...
  • Page 38 APPENDIX A The example below is a generic system diagram and is for reference purposes only. Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 39: Cable And Connector Maintenance

    C ABLE AND CONNECTOR APPENDIX C H A P T E R B MAINTENANCE POWER AND RCM - SPRAYER HARNESS MAINTENANCE 1. Disconnect the RCM - Sprayer harness connector and inspect for signs of moisture or corrosion. 2. If moisture of corrosion is detected, use Deoxit D5, brushes, and compressed air to clean and dry the connector.
  • Page 40 APPENDIX B 2. Spray the connection with a deoxidizing agent (DeoxIT D5 is recommended (P/N 222-4001-006)). FIGURE 1. Deoxidizing Agent Applied to Connection 3. Clean contacts with a small wire brush (P/N 321-0000-477). FIGURE 2. Connection Contact Cleaning 4. Spray the contacts again with the deoxidizing agent. This will rinse out debris. 5.
  • Page 41 FIGURE 3. Compressed Air Applied for Drying 7. If not already applied, apply a single short burst of corrosion inhibitor (Corrosion X HD (Raven P/N 222-0000- 020 or available from http://www.corrosionx.com/corrosionx-heavy-duty.html)) into the NCV connection. Be sure the corrosion inhibitor has coated the NCV contacts and recessed portions of the connector.
  • Page 42 APPENDIX B Hawkeye® 2 Installation Manual for Case IH Patriot/Trident (MY 2017 and Newer)
  • Page 43 Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility.
  • Page 44 Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility.

Table of Contents