Page 1
SCS 440/450/460/660/661 Consoles Universal CAN AccuBoom Installation Manual P/N 0160-0171-073 Rev C 01/17 E28992 Copyright 2017...
Page 2
GPS, GNSS, SBAS, etc.). Therefore, Raven Industries cannot guarantee the accuracy, integrity, continuity, or availability of these services and cannot guarantee the ability to use Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services.
CHAPTER INTRODUCTION ____________________________________________________________ Congratulations on your purchase of the Raven AccuBoom system! This system is designed to provide worry free turn on and turn off of your booms with respect to the as-applied coverage map. The following instructions are designed to assist you in the proper installation of the AccuBoom system.
Page 4
Manual #016-0171-073 Rev. C 01/17 Kit, CANBus, Terminators & Power Adapter “T” – P/N 117-0159-923 Appropriate length CANBus Tee Cable: 6 inch CAN Tee Cable – 115-0171-364 6 Ft CAN Tee Cable – 115-0171-326 12 Ft CAN Tee Cable – 115-0171-362 18 Ft CAN Tee Cable –...
___________________________________________________________ Use the following procedure to properly install the CAN AccuBoom Serial Console cable: 1. Connect the CAN AccuBoom/Serial Console Cable P/N 115-1001-003 to the Raven console. Important! The CAN AccuBoom/Serial Console Cable P/N 115-1001-003 is compatible with Raven SCS440, SCS450, SCS460, SCS660, and SCS661 consoles only.
Page 6
Manual #016-0171-073 Rev. C 01/17 b. Connect the CAN AccuBoom/Serial Console Cable P/N 115-1001- 003 to the back of the Raven console. c. Connect the console cable previously disconnected to the mating connector on the CAN AccuBoom/Serial Console Cable P/N 115-...
Page 7
Manual #016-0171-073 Rev. C 01/17 2. Connect the CAN AccuBoom cable to the CAN AccuBoom node. a. Connect the rectangular connectors from the CAN AccuBoom/Serial Console Cable P/N 115-1001-003 to the CAN AccuBoom Node P/N 063-0172-316. 3. Mount The CAN AccuBoom Node. a.
Page 8
1001-003. c. Connect the other end of the wire to the output of the master spread/hold switch. Note: Raven SCS440/450 consoles have the master switch in the control console. The CAN AccuBoom/Serial Console Cable P/N 115-1001-003 is pre-wired to the master switch in the control console.
Page 9
CAN INSTALLATION ________________________________________________________________________ If the machine you are working on does not currently have a Raven CAN system, you will need a Kit, CANbus, Terminators & Power Adapter “T” P/N 117-0159-923. This kit contains the CAN Cable Adapter Tee With Power P/N 115-0171-368 and two (2) CANBus Terminators P/N 063- 0172-369.
Page 10
Manual #016-0171-073 Rev. C 01/17 2. Connect the CAN bus to the Controller. a. Connect CAN Terminator P/N 063-0172-369 to one connector on the Can Cable Adapter Tee With Power P/N 115-0171-368. CAN Terminator b. Connect the second connector on the CAN Cable Adapter Tee With Power P/N 115-0171-368 to the CAN connector on the Envizio or Viper interface cable.
Manual #016-0171-073 Rev. C 01/17 CHAPTER SYSTEM TROUBLESHOOTING ________________________________________________________________________ The CAN AccuBoom Node P/N 063-0172-316 has additional features to allow the user to diagnose the AccuBoom system. The CAN AccuBoom node has a plastic window in the case that allows the user to view green diagnostic lights.
Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility. The Return...
Page 13
How Can I Get Service? Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval.