Appendix F
A % tier disable is also provided. The % tier disable sets the percent of overlap of the spray volume as the
volume per minute required decreases. Thus, if the % tier disable is set to 10% and the tier 2 switch point is set
at 30 GPM [113.6 L/min], then tier 1 and 2 will switch to tier 2 only when the desired volume decreases to 27
GPM [102.2 L/min].
So, for rates in gallons per minute:
30 GPM – (10% of 30 GPM) = 30 GPM – 3 GPM = 27 GPM
or, for rates in liters per minute:
113.6 L/min – (10% of 113.6 L/min) = 113.6 L/min – 11.3 L/min = 102.3 L/min
In operation, as the volume per minute increases, the following boom tier switching will occur.
10 GPM [37.8 L/min] increasing to 20 GPM [75.7 L/min] tier 1 turned on
20 GPM [75.7 L/min] increasing to 30 GPM [113.6 L/min] tier 2 turned on
30 GPM [113.6 L/min] increasing to maximum flow rate tier 1 and 2 turned on
10 - 20 GPM
37.8 - 75.7 L/min
1
In operation, as the volume per minute decreases, the following boom tier switching will occur.
Maximum flow rate decreasing to 27 GPM [102.2 L/min] tier 1 and 2 turned on
27 GPM [102.2 L/min] decreasing to 18 GPM [68.1 L/min] tier 2 turned on
18 GPM [68.1 L/min] decreasing to 10 GPM [37.8 L/min] tier 1 turned on
Max. Flow - 27 GPM
Max. Flow - 102.2 L/min
1
264
20 - 30 GPM
75.7 - 113.6 L/min
2
1
27 - 18 GPM
102.2 - 68.1 L/min
2
1
30 GPM- Max. Flow
113.6 L/min - Max. Flow
2
1
18 - 10 GPM
68.1 - 37.8 L/min
2
1
Viper Pro Installation & Operation Manual
2
2