Select one of the following application types for the selected product channel or control node:
5.
Note:
Depending upon the type of node, or capabilities of each node, connected to the CANbus network,
additional options may be available or the following options will be restricted. Contact a local
Raven dealer for additional assistance or information on controlling specific applications not listed
below.
Liquid. Application of liquid products.
Note:
Sidekick Pro injection systems will display application type options for a high volume or low
volume pump when the integrated motor control node is detected on the CANbus for the selected
control channel. Sidekick motor control nodes for legacy injection systems will be controlled using
either the Liquid or Granular application type.
Gran (Granular) 1. Dry or granular product application using a single encoder to meter application equipment
with a single bed.
Gran (Granular) 2. Dry or granular product application using a single encoder to meter application from
equipment with a dual bed.
Gran (Granular) 3. Dry or granular product application using a dual encoder configuration to meter application
from equipment with a dual bed.
Gran (Granular) 4. An air seeder system on which a seed gate or segmented meter roller is used to control
seed for active sections before the seed has entered the air system. Most air seeder control systems will be
controlled using this application type selection.
Gran (Granular) 5. An air seeder system on which a manifold or distribution bin is used to control air flow to
active sections after the seed has entered the air system. This application type will control the RPM of the
meter roller based upon active drill sections.
Note:
An optional OmniSeed authorization key is required for Gran 4 and Gran 5 application types to
enable the field computer to control air seeder control systems. Contact a local Raven dealer for
purchasing information and refer to the Registering the Viper Pro section on page 27 to enter the
activation code to unlock the Gran 4 and Gran 5 application type selections.
Spinner. Select this option for RPM control of spinner speed during field operations.
Note:
A product control node capable of spinner control is required to control the spinner RPM or speed.
If the spinner option is not displayed in the application type options, refer to Appendix D, Updating
CAN Nodes via the Viper Pro, for assistance with updating the control node. Refer to Appendix B,
Calculating the Calibration Values, for additional assistance with the spinner RPM set up.
NH3. An option for anhydrous ammonia rate control operations will be available if the product node is capable
of specific rate control features. It is recommended to ensure this option is available and selected when
controlling the application rate of anhydrous ammonia, master control valve functions, and section valves
during field operations.
NH3 Boost. The anhydrous pump control selection will be available if the product node is capable of specific
control features for the AccuFlow HP boost pump. Select this option to allow the operator configure specific
boost pump control features for field operations.
Repeat the above process for remaining product nodes or control channels as necessary.
6.
Touch OK to save the currently displayed settings and return to the CAN Controller Status screen.
7.
Manual No. 016-0171-122 Rev. I
Initial Set Up and Navigation