Appendix B
PWM Control Valve Tuning
The Viper Pro field computer provides three methods for fine tuning a PWM or PWM close valve used for
controlling product application:
PWM Manual Calibration
The operator may enter the known values for the following PWM valve calibration settings within the Product
Control Settings area:
Min PW
(Minimum Pulse Width)
(Max PW)
Maximum Pulse Width
Note:
The PWM valve will not be operated during manual calibration. It is recommended to verify that
any changes to these settings will have the desired affect before controlling product application.
Refer to the Node Control Settings Screen (Page 2) section on page 140 for more information on
the min pw, max pw values and the Node Control Settings Screen (Page 3) section on page 141
for details on the standby pressure, preset pw and pw freq values.
PWM Calibration Assistance
The calibration assistant allows the operator to manually increase or decrease the PWM output using on-
screen controls and set the PWM minimum, maximum, frequency and preset values based upon observed
operation.
Note:
It is recommended to perform the calibration process with water in liquid tanks or while performing
a catch test with a dry or granular application system.
To use the calibration assistant mode, toggle the vehicle master switch and at least one section to the on
position. To stop the PWM output at any time during the calibration process, toggle the vehicle master switch to
the off position.
Note:
Refer to the Node Control Settings Screen (Page 2) section on page 140 for more information on
the min pw, max pw values and the Node Control Settings Screen (Page 3) section on page 141
for details on the standby pressure, preset pw and pw freq values configured using the calibration
assistant.
Touch within the Product Control Settings area on the CAN Controller Status screen. The first Node 1
1.
Settings screen will display.
236
Standby Pressure
Pre Set PW
(Preset Pulse Width)
WARNING
The PWM valve output will increase and
decrease as the up and down arrows are
selected. Keep any bystanders away from
areas where product may be expelled and
moving components when performing the
calibration process.
Viper Pro Installation & Operation Manual
PW Freq
(Pulse Width Frequency)