Raven Viper Pro Installation & Operation Manual page 88

Software version 3.10
Hide thumbs Also See for Viper Pro:
Table of Contents

Advertisement

Chapter 5
If Swath Guidance was selected, select the guidance pattern best suited to the field area and application.
6.
Refer to the Swath Guidance Patterns section on page 110 for details on the available patterns and using
guidance during a job.
Press Next. If AccuBoom Control was selected on the New Job screen, select one of the following
7.
AccuBoom mapping modes for the job:
Standard AccuBoom - This method requires no action or additional setup by the operator. The
operator simply begins to apply product to the field and the Viper Pro monitors the coverage map
and will turn sections off if the boom enters into a previously applied area.
Create AccuBoom No-Spray Map - This method allows the operator to define spray/no-spray
zones within the field. This method is typically used if no previous map has been created and the
operator wants to define the field boundaries and other boundaries such as waterways, well
heads, etc.
Load AccuBoom No-Spray Map - This method allows the operator to load a previously created
spray zone map. Select the desired map from the list of available AccuBoom maps currently
stored on the Viper Pro.
Create Map From Field Boundary - This method allows the operator to select an existing field
boundary and generate a no-spray boundary map from the field boundary map. The operator is
given a list of all scout files available and allowed to select the desired map. The boundary must
be one previously created by the Viper.
Note:
See Chapter 9, Using AccuBoom™, for details on setting up the AccuBoom feature.
78
Viper Pro Installation & Operation Manual