Raven Viper Pro Installation & Operation Manual page 146

Software version 3.10
Hide thumbs Also See for Viper Pro:
Table of Contents

Advertisement

Chapter 8
Node Feature Settings Screen (Page 2)
From the CAN Controller Status screen, touch within the Features Settings area to display the first Node
Settings screen and select the Next button to access the following alarm and feature settings.
Zero Speed Shutoff. Enable the zero speed shutoff feature to allow the field computer to automatically shut
off product application if the vehicle speed is slower than 0.7 mph [1.1 km/h]. If the zero speed shutoff feature
is engaged during a job, the Viper Pro will also display a zero speed alert.
Note:
The zero speed shutoff feature only affects products set to automatic control. Products controlled
manually will continue to be applied even if the zero speed shutoff feature is engaged.
To restart product application after the zero speed shutoff feature has engaged, cycle the master switch 'Off'
and then back 'On.' The zero speed shutoff feature will reactivate if the vehicle does not achieve a speed
greater than 0.7 MPH [1.1 km/h] and maintain that speed for more than 10 seconds.
Note:
If an optional AccuBoom system is connected, the AccuBoom override may be enabled to begin
product application from a complete stop. Refer to the Enabling AccuBoom™ Override section on
page 178 for more information.
Vacuum/Bin Alarm. The vacuum/bin alarm must be disabled for nodes or channels configured for standard
(non-injection) liquid product application control.
Enable the vacuum alarm feature if an injection pump is controlled via a CAN product control or motor
control node. When activated, the vacuum alarm displays an alert if the injection pump cannot draw product
from the supply tank.
Enable the bin alarm for granular applications if an optional bin level sensor is installed. With this feature
enabled, the Viper Pro will display an alert when the sensor detects the product level in the bin falls below
the sensor level.
Note:
Contact a local Raven dealer for information on injection systems or bin level sensors.
Flow/Shaft Alarm. Enable the flow/shaft alarm to display an alert if the field computer does not detect a signal
from the pump shaft encoder or flow switch. This alarm may be used to help troubleshoot flow errors with a
CAN motor control node.
Note:
This feature is currently not used with the Raven Sidekick Pro injection system.
Decimal Shift. Enable the decimal shift feature to increase the system accuracy for low application rates. In
the standard mode, the Viper Pro displays values to one decimal place. With the decimal shift feature enabled,
values will be displayed to two decimal places.
Note:
Verify all calibration values after the decimal shift feature is either enabled or disabled. Change
settings as necessary.
136
Viper Pro Installation & Operation Manual

Advertisement

Table of Contents
loading

Table of Contents