Canon MF8580Cdw Service Manual page 255

Mf8500/mf8200 series
Hide thumbs Also See for MF8580Cdw:
Table of Contents

Advertisement

4
Disassembly/Assembly > Controller System > Removing the Main Controller PCB > After replacing main controller PCBs
■ After replacing main controller PCBs
1. Setting of destination/paper size group
1) COPIER > OPTION > BODY > LOCALE (to set destination groups)
[Settings]
1: Japan, 2: North America, 3: Korea, 4: China, 5: Taiwan, 6: Europe, 7: Asia,
8: Oceania
2) COPIER > OPTION > BODY > SIZE-LC (to set paper size groups)
[Settings]
1: AB series, 2: Inch series, 3: A series, 4: AB/Inch series
2. Clearing Setting/Registration data
1) COPIER > FUNCTION > CLEAR > ALL (to clear all data)
Once executed, the following data are cleared according to the values of LOCALE and
SIZE-LC set in step 1.
• Setting / Registration data (the default value for each destination is set).
• Service mode data (the default value for each destination is set).
• Job IDs
• Log data
• Dates
2) COPIER > FUNCTION > CLEAR > R-CON (to clear default setting values for the
reader/DF)
3. Adjustment, input of default setting values
1) Close the ADF.
2) COPIER> FUNCTION > CCD > CL-AGC, BW-AGC (to adjust white levels)
The white level is adjusted.
3) Enter default setting values indicated on the service label in the corresponding service
mode items.
4) COPIER> FUNCTION > VIFFNC > STOR-DCN (to back up DC controller setting
values)
Purpose: to be prepared for replacing DC controller PCBs
5) Turn off and on the power.
6) Start in the initial installation mode. Follow instructions shown on the screen for setup.
(setting of date/time, auto-gradation correction)
4
Disassembly/Assembly > Controller System > Removing the Main Controller PCB > After replacing main controller PCBs
4. Migrating the serial number
1) Enter the serial number (8-digit alphanumeric) in Settings/Registration > System
Settings > Device Information > Location.
2) Select COPIER > OPTION > SERIAL > SN-MAIN. Then, press the OK key to write the
serial number entered in step 1 in the Main Controller PCB. After it has been written,
the serial number entered in "Location" in step 1 is deleted.
3) Turn OFF and then ON the main power.
4) Execute COPIER > FUNCTION > MISC-P> SPEC to output the spec report to check
the serial number BODY.No..
5) Enter the data of the installation location (which was written down in "Before replacing
the Main Controller PCB") in Settings/Registration > System Settings > Device
Information > Location.
5. Migrating user data
In Remote UI, perform the following procedure to import the user data (login in
administrator mode).
In Setting/Registration > Import/Export > Menu > Import, select an item and then start
import.
6. Migrating service mode data
In service mode, perform the following procedure to import the service mode data.
FUNCTION > SYSTEM > IMPORT
7. Reinstall the drivers.
1) Uninstalling Old Drivers.
• Printer Driver
• FAX Driver
• Scanner Driver
• Network Scan Utility. (for machines with network connection)
* As for the procedure, refer to "Uninstalling the Software" in the Starter Guide.
2) Install the drivers which have been uninstalled in step 1.
* As for the procedure, refer to the following items in the Starter Guide.
• In case of network connection: "Installing via Network Connection"
• In case of USB connection: "Installing with USB Connection"