Download Print this page

Canon MF8580Cdw Service Manual page 389

Mf8500/mf8200 series
Hide thumbs
Also See for MF8580Cdw 
Manual - 750 pages
User manual - 750 pages
Getting started - 292 pages

Advertisement

■ BUSY TONE 1
● Bit Switch
Bit No.
Function
Bit 0
-
Bit 1
-
Bit 2
Signal frequency
Changed
Bit 3
RBT signal detection
Yes
Bit 4
Judgment of intermittent
Start from valid ON
signal
signal
Bit 5
RBT signal check cycle
1 cycle
Bit 6
Signal form
Continuous
Bit 7
Signal detection
Detected
● Numeric value parameter
Parameter No.
Function
01;
-
02;
T1 timer
03;
T2 timer
04;
T3 timer
05;
T4 timer
06;
Signal detection table
07;
Signal detection level
08;
Number of signal frequency
8
Service Mode > FAX > Setting of NCU Parameters > MULTI
1
0
M82 M85
-
-
-
-
-
-
Not changed
-
No
-
Start from either valid
-
ON signal or OFF signal
1/2 cycle
-
Intermittent
-
Not detected
T-8-36
Setting range
M82 M85
-
-
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 16
0 to 7
0 to 9999
T-8-37
8
Service Mode > FAX > Setting of NCU Parameters > MULTI
■ REORDER TONE
● Bit Switch
Bit No.
Function
-
Bit 0
-
-
Bit 1
Signal detection method
-
Bit 2
Signal frequency
-
Bit 3
-
Bit 4
Judgment of intermittent
-
signal
-
Bit 5
-
-
Bit 6
Signal form
Bit 7
Signal detection
● Numeric value parameter
Parameter No.
-
01;
02;
T1 timer
03;
T2 timer
04;
T3 timer
05;
T4 timer
06;
Signal detection table
07;
Signal detection level
08;
Number of signal frequency
■ MULTI
Not in use
1
-
FED
FR3
Changed
Not changed
-
start from valid ON
start from either valid
signal
ON signal or OFF signal
-
Continuous
Intermittent
Detected
Not detected
Function
Setting range
-
-
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 16
0 to 7
0 to 9999
8-41
0
M82 M85
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
T-8-38
M82 M85
-
-
T-8-39
8-41