Replacement
Replacement is the reverse of the removal procedure. Ensure that the front support finger and
rear support finger are aligned correctly.
Repairs and Adjustments
REP 12.6, REP 12.7
REP 12.7 Ejector Assembly and Support Finger Assembly
Parts List on PL 12.25 and PL 12.40
Purpose
This procedure is used to repair the following components:
NOTE: Only perform the steps that are necessary to repair the damaged component.
•
Ejector assembly, PL 12.40 Item 16.
•
Support finger assembly, PL 12.25 Item 20.
•
Support finger motor, PL 12.25 Item 2.
•
Ejector motor, PL 12.40 Item 1.
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1.
Remove the front jogger assembly and rear jogger assembly, REP 12.5.
2.
Remove the left cover, refer to REP 12.2.