Xerox WorkCentre 4150 Service Manual page 205

All-in-one laser mfp a3
Hide thumbs Also See for WorkCentre 4150:
Table of Contents

Advertisement

3.
Prepare to remove the ejector assembly and support finger assembly, Figure 1.
1
Remove 1 screw.
Figure 1 Preparation
WorkCentre 4150
3
Lower the finisher PWB.
2
Remove 1 screw.
September 2006
4.
Remove the ejector assembly and support finger assembly, Figure 2.
NOTE: The ejector assembly and support finger assembly are removed as a unit.
4
Remove the ejector
assembly and the
support finger assem-
bly.
1
Remove 2 screws.
Figure 2 Removal
5.
If necessary, remove the support finger motor, PL 12.25 Item 2.
4-61
3
Disconnect 1
connector.
2
Disconnect 3 bulk-
head connectors.
Repairs and Adjustments
REP 12.7

Advertisement