REP 12.2 Finisher PWB
Parts List on PL 12.10
Removal
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1.
Remove the finisher, REP 12.1.
2.
Remove the finisher covers, REP 12.4.
3.
Remove the stacker tray support, PL 12.45 Item 2.
4.
Remove the left cover, Figure 1.
3
2
Remove the left
Disconnect the stacker top
cover.
sensor.
Figure 1 Left cover removal
5.
Disconnect all connectors on the finisher PWB, PL 12.10 Item 8.
Repairs and Adjustments
REP 12.2
6.
Remove the finisher PWB.
Replacement
If a new Finisher PWB is to be installed, check that the dip switch settings are correct. Refer to
the 12A Finisher PWB DIP Switch Settings RAP. Replacement is the reverse of the removal
procedure.
1
Remove 2 screws
from the front and 2
from the rear.
September 2006
4-52
WorkCentre 4150