REP 7.3 Tray 1 Paper Size Detect PWB
Parts List on PL 7.15
Removal
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1.
Remove paper tray 1.
2.
Remove the rear cover, PL 28.10 Item 6.
3.
Disconnect CN15 on the main PWB. Release the harness from the cable clamps. Discon-
nect the tray 1 near empty sensor inline connector.
4.
Remove the tray 1 paper size detect assembly, Figure 1.
1
Remove 3 screws.
Figure 1 Removal
WorkCentre 4150
5.
Replacement
Replacement is the reverse of the removal procedure.
2
Remove the tray 1 paper
size detect assembly.
September 2006
4-29
Remove the paper size detect PWB from the housing (2 screws).
Repairs and Adjustments
REP 7.3