Replacement
CAUTION
Do not damage the fuser stripper fingers when reinstalling the heat roller assembly, refer to
Figure 3.
1.
Replacement is the reverse of the removal procedure.
2.
Ensure the locating tabs on the front heat roller collar are position in the recesses on the
heat roller, refer to Figure 3.
3.
Ensure that the spring on the front jam lever is positioned in the slot on the fuser frame.
4.
If a new heat roller assembly or pressure roller are installed, reset the HFSI count to zero.
Go to GP 16 High Frequency Service Items.
Repairs and Adjustments
REP 10.5, REP 10.6
REP 10.6 Fuser Connector
Parts List on PL 4.15
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1.
Remove the exit guide assembly, REP 10.2.
2.
Remove the fuser connector retainer, PL 4.15 Item 21.
3.
Remove the fuser connector, Figure 1.
1
Disconnect the ground
connector.
Figure 1 Fuser assembly separation
Replacement
Replacement is the reverse of the removal procedure.
September 2006
4-50
WARNING
WARNING
CAUTION
3
Remove the fuser
connector.
2
Disconnect CON3, CON8
and CON9 from power
supply unit 2.