50
Fb13
ActiveNrPDOUTS
Indicates the number of active PDOUT units in normal mode.The value of
this parameter usually corresponds to the value of FB11. The cause that
the two parameter values differ is that the connected drive converter control
supports only one PDOUT unit.
028Dh
0
Uint8
1 (corresponds to 8 byte PDOUT data)
2 (corresponds to 16 byte PDOUT data)
1 (corresponds to 8 byte PDOUT data)
The value of this parameter can only be read.
Fb14
PdoutEvcnt
Counts the events that new PDOUT data are received from PROFINET.
028Eh
0
Uint32
1
0
The value of this parameter can only be read.
Fb15
Pdout_Dw1
Displays the last received first double word (32 bit) of the PDOUT data.
028Fh
0
Uint32
1
0
The value of this parameter can only be read.