Table 2: Description Of The Leds - KEB COMBIVERT F5 Instructions For Use Manual

Installation f5 profinet operator
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

OVERVIEW OF THE cONTROL ELEMENTS
LED1
LED2 Acyclic data access
LED3 Flashes, as long as process data access to the drive converter is running. If
LED4 Flashes, if a link is recognized at PROFINET Port0 or Port1.
LED5 Serves as identification LED. This LED can be controlled from the PROFINET
LED6
Table 2:
14
Flashing
Double blinking (200ms
ON/200ms OFF/200ms
ON/1000ms OFF)
Constantly off
Constantly on
Blinking (500ms ON/500ms OFF) PROFINET communication completely
the synchronous mode as well as the IRT communication is active, the LED
is flashing like LED1.
master via the discovery and configuration DCP set service.
Flashing
Constantly off
Blinking (500 ms ON/500 ms
OFF) for 3 s
Flashing
Constantly off
Blinking (500 ms ON/500 ms
OFF)
Fast blinking (50 ms ON/50 ms
OFF)
Double blinking (200ms
ON/200ms OFF/200ms
ON/1000ms OFF)
Constantly on
Description of the LEDs
Actual condition
PROFINET firmware not ready
PROFINET firmware ready
PROFINET communication completely
started, internal communication asyn-
chronous
started, internal communication synchro-
nous
Actual condition
non-operated
DCP set service with signal = FLASH_
ONCE
Actual condition
No voltage supply at the drive converter
control unit
Drive converter control in error status
No information obtained from the drive
converter
Fatal error during initialization. No func-
tion of the operator!
Can occur e.g.:
- no valid KEB MAC address assigned.
- inconsistent configuration.
No error