PARAMETER DEScRIPTION
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
44
Fb01
FBS Config
Some configuration settings of the F5 PROFINET operator
0281h
0
Uint16
b15...b7
b6
b5
xxx
Pnet_
Enable_
SubIdx_
PDMap
Linear
bit0 = 1
IRT_Enable: In preparation
bit1 = 1
SyncMode_Enable: Enables the internal cyclic communication.
bit2 = 1
Disable NetX-Reset: At fundamental problems when starting the
PROFINET firmware, the CPU of the PROFINET operator can
carry out a hardware reset of the PROFINET ASIC (NetX). This
function can be disabled via this bit.
bit3 = 1
PDAPI_Disable: For the function to be able to exchange acy-
clic data with a standard Siemens S7 PROFINET controller to
PROFIDRIVE Base Mode Parameter Access, the F5 PROFINET
operator has a second API with value = 3A00h. The module with
the name ,ProfiDrive_PAP' is assigned to this API. Via this bit the
complete functionality of the API = 3A00h can be disabled with the
module ,ProfiDrive_PAP'. In this case the acyclic communication
to PROFIDRIVE Base Mode-Parameter-Access can be executed
also via the standard API with value = 0.
bit4 = 1
The default PD mapping is written when starting the software to
the drive converter, if bit5 = 1.
bit4 = 0
The non-volatile stored PD mapping in the operator (see Fb28 to
Fb31) is written to the drive converter at boot-up, if bit5 = 1.
bit5 = 0
Writing the PD mapping to the drive converter control is deactivat-
ed at boot-up.
bit5 = 1
Writing the PD mapping to the frequency inverter control is activat-
ed at boot-up.
bit6 = 1
When addressing the parameters to PROFINET acyclic data the
subindex is not bit-coded, but linearly coded.
bit7 = 1
Activation of the PROFINET alarm signals. When the alarm is
activated, the operator monitors the value of the drive converter
parameter ru00 „inverter state" (see chapter 3.11).
0
A new value is stored non-volatile, but only active at the next switch on.
b4
b3
b2
Use_De-
PDAPI_
Disable_
fault_
Disable
NetX_
PDMap
Reset
b1
b0
Sync-
IRT_En-
Mode_
able
Enable