PARAMETER DEScRIPTION
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
38
OS05
Diag baud rate
Indicates the adjusted transmission speed of the diagnostic interface (X6B).
0185h
0
Uint8
0: 1200 Bit/s
1: 2400 Bit/s
2: 4800 Bit/s
3: 9600 Bit/s
4: 19200 Bit/s
5: 38400 Bit/s
6: 55500 Bit/s
5: 38400 Bit/s
A changed value is stored immediately active and non-volatile.
OS09
HSP5_MinTxGap
Specifies the minimum gap time between two HSP5 Tx telegrams. This pa-
rameter value is determined after each power on by the connected FI control.
This parameter may only be changed for test purposes.
0189h
0
Uint16
1 µs
0 (off)
A changed value becomes active immediately but it is not stored.
If a value above the upper limit of 500 μs is written, the upper limit of 500 μs
becomes active.
OS10
MAc Address (chassis)
018Ah
0
Uint32
1
FAXXXXXXh
The complete value of the MAC address (chassis) is the result from this
value plus prefix of 0008h.