KEB COMBIVERT F5 Instructions For Use Manual page 35

Installation f5 profinet operator
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

PARAMETER OVERVIEW
Sub-In-
PNU
ID
dex (*1)
0192h
0
OS18 MAC Address(Port1)
0193h
0
OS19 Manufacturer_Id(IM)
0194h
1,2,4,8,16 OS20 Order_Id (IM)
0195h
0
OS21 Hardware_Revision (IM)
0196h
0
OS22 Software_Revision (IM)
0197h
0
OS23 Revision_Counter (IM)
0198h
0
OS24 Profile_Id (IM)
0199h
0
OS25 Profile_Specific_Type
019Ah 0
OS26 Pnet_IPMask
0198h
0
OS27 Pnet_IPGateway
0280h
0
Fb00
0281h
0
Fb01
0282h
Fb02
0283h
0
Fb03
0284h
0
Fb04
0285h
0
Fb05
0286h
0
Fb06
0287h
0
Fb07
0288h
0
Fb08
0289h
0
Fb09
028Ah 0
Fb10
028Bh 0
Fb11
028Ch 0
Fb12
028Dh 0
Fb13
028Eh 0
Fb14
028Fh
0
Fb15
(*1)
Please note that the use of the sub-index is depending on the actual setting of bit6 in parameter
Fb01 FBS Config, see chapter "3.1.1.2 Addressing with subindex". „3.1.1.2 Satzadressierung
mittels Subindex"
Name
(IM)
InternComCycle
FBS Config
DelayTimeSyncToApplIrq Uint16
RealSyncCycleTime
FBS Command
PDOUT1_Hsp5Service
PDIN1_Hsp5Service
PDIN_Cycle
PDOUT2_Hsp5Service
PDIN2_Hsp5Service
CfgNrPDINS
CfgNrPDOUTS
ActiveNrPDINS
ActiveNrPDOUTS
PdoutEvCnt
Pdout_DW1
Internal
Meaning
data type
Uint32
Less significant 32-Bit of the MAC ad-
dress for Port1 (X6D) of the operator
Uint16
Manufacturer-ID
String[20]
Order number of the operator
Uint16
Hardware revision of the operator
Uint32
Software revision of the operator
Uint16
Revision counter
Uint16
Profile-ID
Uint16
Profile specific type
Uint32
Actual IP mask
Uint32
Actual IP Gateway setting
Uint32
Cycle time in synchronous mode in µs
Uint16
Collection of some configuration set-
tings
Delay time between IRT synchsignal
and internal synchronous communica-
tion in µs
Uint16
The real cycle time of the IRT synchsig-
nal in µs determined by the operator
Uint16
Setting of certain commands to the F5
PROFINET operator.
Uint8
Service number for the KEB internal
protocol for reading the first 8 bytes
PDOUT data
Uint8
Service number for the KEB internal
protocol for reading the first 8 bytes
PDIN data
Uint16
Cycle time in ms for reading the PDIN
data
Uint8
Service number for the KEB internal
protocol for reading the second 8 byte
PDOUT data
Uint8
Service number for the KEB internal
protocol for reading the second 8 byte
PDIN data
Uint8
Required number of PDIN units
Uint8
Required number of PDOUT units
Uint8
Number of active PDIN units
Uint8
Number of active PDOUT units
Uint32
Counts the events of received PDOUT
data
Uint32
Actual PDOUT data bytes 0...3
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents