STANDARD PROjEcT DESIGN
If the synchronous communication (PROFINET IO-IRT) shall be used, the PN-IO inter-
face of the CPU can be configured by right-clicking on the PN-IO interface of the CPU
and select object properties as a sync master:
Figure 8:
Then in the right part of the HW Config window of PROFINET-IO → additional field
instruments → ....the KEB F5 PROFINET operator selected and appended with the
mouse to the PROFINET System in the left pane. It is important that the PROFIDRIVE_
PAP module is set into slot 3:
Figure 9:
As standard one 4x16 bit input module and one 4x16 bit output module are automatically
inserted for the KEB F5 unit. If required, these can be replaced by one 8x16 bit input
module or 8x16 bit output module. The standard project design is used in this example.
Thereby 8 byte cyclic data can be transferred from the control to the slave and the same
quantity cyclic data can be transferred from the slave to the control. The project design is
completed herewith if no synchronous communication is required (PROFINET IO-IRT).
Configure object properties as sync master
PROFINET system
61