PARAMETER DEScRIPTION
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
OS26
Pnet_IPMask
Indicates the actual IP mask of the F5 PROFINET operator.
019Ah
0
Uint32
4-byte IP-Mask
0.0.0.0
The last assigned IP mask by the PROFINET controller is stored non-volatile
and remains active at the next start-up.From software V3.2 the value of this
parameter can also be written via diagnostic interface. A new value is stored
non-volatile, but active only at the next switch on.
OS27
Pnet_IPGateway
Indicates the actual IP Gateway setting of the F5 PROFINET operator.
0198h
0
Uint32
4-byte IP-Gateway
0.0.0.0
The last assigned IP Gateway adjustment by the PROFINET controller is
stored non-volatile and remains active at the next start-up.From software
V3.2 the value of this parameter can also be written via diagnostic interface.
A new value is stored non-volatile, but active only at the next switch on.
Fb00
Interncomcycle
Indicates whether the internal communication is cyclic or acyclic.
0280h
0
Uint16
0: Internal communication is acyclic
Otherwise: Internal communication is cyclic with cycle time = Fb00 in µs
0