Fb02
DelayTimeSyncToAppllrq
Is only relevant for the synchronous communication mode (PROFINET IO/
IRT). This parameter defines the delay time between PROFINET-Sync-Sig-
nal and communication interrupt.
0282h
0
Uint16
1 µs
500 µs
A changed value is stored immediately active and non-volatile.
Fb03
RealSynccycleTime
Specifies the determined synchronous cycle time of the F5 PROFINET oper-
ator. The calculation of this time is updated with each Sync signal.
0283h
0
Uint16
1 µs
This parameter is read-only.
Fb04
FbS command
Certain commands in the F5 PROFINET operator can be requested via this
parameter. After execution of the command the operator sets bit 15 of the
value to 1.
0284h
0
Uint16
0: no command
1: Sets all non-volatile stored parameters of the operator to default values.
0