13. Install the new module in reverse order.

Capacitors

The DC circuit of the power modules of the drive contain several electrolytic capacitors.
Their lifespan depends on the operating time of the drive, loading and ambient temperature.
Capacitor life can be prolonged by lowering the ambient temperature.
Capacitor failure is usually followed by damage to the unit and an input cable fuse failure,
or a fault trip. Contact ABB if capacitor failure is suspected. Replacements are available
from ABB. Do not use other than ABB specified spare parts.

Reforming the capacitors

The capacitors must be reformed if the drive has been stored for a year or more. The
manufacturing date is on the type designation label. For information on reforming the
capacitors, see Converter module capacitor reforming instructions (3BFE64059629 [English]).

Fuses

Replacing AC fuses (frames R6 and R7)

WARNING!
Obey the instructions in chapter
death, or damage to the equipment can occur.
1. Stop the drive and do the steps in section
you start the work.
2. Open the cabinet door.
3. Remove the shrouding from in front of the switch fuse.
11
12
Safety
Electrical safety precautions (page 16)
13
instructions. If you ignore them, injury or
Maintenance 145