IP code

IP21

against ingress of solid foreign objects >12.5 mm
IP42
against ingress of solid foreign objects > 1 mm
IP54
dust-protected
IP21
The degree of protection of the standard drive cabinet is IP21. With doors open, the degree
of protection of the standard cabinet and all cabinet options is IP20. The live parts inside
the cabinet are protected against contact with clear plastic shrouds or metallic gratings.

IP42 and UL Type 1 (option +B054)

This option provides the degree of protection of IP42 (UL type 1). The air inlet gratings are
covered with a metallic mesh between the inner and outer metallic gratings.

IP54 and UL Type 12 (option +B055)

This option provides the degree of protection of IP54 (UL type 12). It provides the cabinet
air inlets with filter housings containing folded board air filter mats between the inner and
outer metallic gratings.

UL listed (option +C129)

The option includes factory inspection of the cabinet according to UL 508C and the following
accessories and features:
US type main switch fuse
US cable conduit entry (plain plate without ready-made holes)
all components UL Listed/Recognized
maximum supply voltage 480 V.
Related options: +H351 (top entry of cables), +H353 (top exit of cables) and +H358 (cable
conduit entry)

Plinth height (options +C164 and +C179)

The standard height of the cabinet plinth is 50 mm. These options specify a plinth height of
100 mm (+C164) or 200 mm (+C179).

Empty cubicles (options +C196 to +C201)

Note:
This option is available for US only.
These options add an empty cubicle to the drive cabinet: The cubicle is equipped with blank
power cable entries both at the top and the bottom.
on the right-hand side of the converter cubicle (400 mm wide with option +C196, 600
mm wide with option +C197 and 800 mm wide with option +C198)
on the left-hand side of the converter cubicle (400 mm wide with option +C199, 600 mm
wide with option +C200 and 800 mm wide with option +C201).
The equipment is protected ...
First numeral
Operation principle and hardware description 39
Second numeral
against dripping (vertically falling drops)
against dripping (15° tilting) water
against splashing water