Adjust the Image
2. Loosen the right boresight set screw (B).
3. Turn the right boresight cap screw (A) 1/16 of a turn clockwise.
4. Adjust the left boresight cap screw (D) equally in the opposite direction.
5. If the quality of the projected image has not improved, turn the right boresight cap screw 1/16 of
turn counter-clockwise. Make sure the left adjuster is adjusted equally in the opposite direction.
6. Check the screen each time an adjustment is made. The right-side adjustments affect the top-
right and bottom-left points on the screen. Once both cross hairs are in focus, lock the set screw
for right boresight.
7. Repeat Steps 5 to 7 for the left-side.
12
Right Boresight Cap Screw
A
Right Boresight Set Screw
B
Left Boresight Set Screw
C
Left Boresight Cap Screw
D