Christie CP2215 Service Manual page 24

Hide thumbs Also See for CP2215:
Table of Contents

Advertisement

Adjust the Image
Field
Output Delay
Phase Delay
h. Tap Activate to activate the channel.
4. Display a RGB-12bit-Full Screen White test pattern:
a. On the touch panel controller (TPC), tap the Test Pattern icon (
b. Tap All Test Patterns.
c. Tap RBG-12bit-Full Screen White.
5. Measure the color point of the pattern with the spectroradiometer and verify that the values are
within these tolerances:
Red
Green
Blue
White
If the values are outside the tolerances:
a. Remove the top lid. See
b. Remove the front skin. See
c. Loosen the 2 adjustment screws on the yellow notch filter.
16
The non-image time in Microseconds (μ). Offset 3D stereo
sync output in relation to dark time interval. Acceptable
values are between -32768 and 32767. A positive offset
adds a delay and a negative offset starts playback early. Tap
Launch Dialog to enter the output delay value.
The degree of reference between the left and right sync
output. Values between -180 and 180 are accepted. Tap
Launch Dialog to enter the phase delay value.
Color
X
0.640
0.280
0.160
0.314
Remove the Top Lid
Remove the Front Skin
Description
Tolerance
Y
+/- 0.002
0.320
+/- 0.002
0.640
+/- 0.002
0.100
+/- 0.002
0.351
on page 22.
on page 22.
) in the taskbar.
Tolerance
+/- 0.002
+/- 0.002
+/- 0.002
+/- 0.002
CP2215 Service Manual
020-101226-03 Rev. 1 (10-2015)

Advertisement

Table of Contents
loading