Parts and Module Replacement
7. Remove the top 2 hex screws and clips holding the cold mirror.
8. Loosen the bottom 2 hex screws holding the cold mirror.
9. Hold the top corners of the mirror, and then pull it up and out. When reinstalling the cold mirror,
make sure the reflective surface faces inward.
10. Recalibrate the Measured Color Gamut Data (MCGD) settings. See the CP2215 User manual.

Remove Fold Mirror 1

Wear gloves when you handle the fold mirror.
Fold Mirror 1 is accessed from the front left-corner of the projector. The alignment screws are
positioned along the top of the light tube, which allows them to be adjusted.
1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the top lid. See
4. Remove the front skin. See
5. Remove the exhaust panel skin. See
6. Disconnect the 2 quick connectors that connect the cooling assembly to the light engine.
7. Remove the contrast aperture. See
8. Remove the light sensor module and move it aside. See
page 51.
9. Remove the 4 hex screws that secure the fold mirror to the IOS.
10. Remove the 3 2.5 mm hex screws.
11. Loosen the 4 screws and the mounting clips from the fold mirror mounting bracket.
52
Remove the Top Lid
on page 22.
Remove the Front Skin
Remove the Exhaust Panel Skin
Remove the Contrast Aperture Plate
on page 22.
on page 26.
on page 50.
Remove the Light Sensor Module